Error: API error: The supplied UserAgent is not allowed: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com) HB012-B-01U1-S12F - Unshielded - RFS Technologies an Amphenol Company
RFS Technologies website is optimized for recent browsers :
IE9+, Chrome 31+, Firefox 31+, Opera 28+, Safari 7+


My e-catalog

HB012-B-01U1-S12F
Unshielded Hybrid Cable, 1 x 1.5mm² pair power cable and 24 x singlemode optical fibers

Rev : A | Rev date : 07 Mar 2023

A hybrid cable designed to transmit both electrical power and optical signals in a single cable.   Two electrical power conductors and two fibre optic sub units, each containing twelve bend insensitive singlemode fibers surround a non metallic strain member. Incorporation of water blocking tapes and a UV stable jacket ensure long term operation in both internal and outdoor applications. The inclusion of fillers ensures the fully circular construction can be efficiently installed in ceiling or floor voids as well as conventional ducting systems

 

FEATURES / BENEFITS

  • Circular construction prevents snagging during installation
  • Bend insensitive optical fiber simplifies installation and termination 
  • Singlemode fiber provides the ultimate future proof support for high bandwidth services
  • Suitable for Indoor/outdoor applications

 

Hybriflex Bulk cable dia.012", Basic/uncreened- DC wire dia 01.5mm² Unshielded, 1 DC pair, SM x 12-pairs, Flame retardant jacket


Technical features

Structure

Cable TypeHybrid (2 x 1.5mm² & 24 x SMF unscreened)
Size1/2"
Fire Performancemeets or exceeds: IEC 60754-1/-2 smoke emission, halogen free, non corrosive IEC 61034 , low smoke IEC 60332-1 flame retardant , IEC 60332-3-24 fire retardant , CPR: class Cca, S1b, d0, a1 to BS EN 13501-6:2014
Number of Fiber24 (2 X 12F sub units)

Mechanical Specifications

Outer Diameter Nominal mm (in)13.8 (0.543)
Cable Weight kg/m (lb/ft)0.21 (0.141)
Minimum Bending Radius, (Operating)mm (in)55 (2.165)
Minimum Bending Radius, (Installation)mm (in)110 (4.331)
Recommended / Maximum Clamp Spacing m (ft)0.6 / 1 (2 / 3.2)
Tensile Strength (Operating)1000 (220) IEC60794-1-2 E3
Tensile Strength (Installation)1800 (397) IEC60794-1-2 E3
Crush Resistance (Operating)2000 IEC 60794-1-2 E3

DC Power Cable Specifications

Number of DC Pairs1
Maximum DC-Resistance Power Cable Ω/km (Ω/kft)13.3 (4.05)
Cross Section of Power Cable mm² (AWG)1.5 (16)
DC Wire Information30 x 0.26 Pure Annealed Copper (Class 5)
DC Wire Jacket MaterialBlue and Grey LSZH polyolefin (colours may change in accordance with B.S. updates)
DC Wire Jacket Thickness mm (in)0.7 (0.028)
DC Cable Diameter mm (in)3 (0.118)
DC Standards (Meets or Exceeds)IEC 60228

Cable Jacket

UV-Protection Individual and External JacketUV Resistance EN 50290-2-24,
Jacket MaterialFlame Retardant IEC60332-1/-3-24, UV Resistance EN 50290-2-24, Halogen Free compliance to IEC60754-1/-2 , Low smoke emission to IEC61034-2

F/O Cable Specifications

F/O Cable Type2 x Dry Loose-tube fibre sub units numbered 1 and 2, fibres in Yellow LSZH jackets with aramid yarn as strength member
Number of F/O Pairs12
Core/Clad µm9 /125
Secondary Protection Nominal µm (in)900 (0.035)
Cable Diameter mm (in)2.5 (0.098)
F/O Cable JacketYellow LSZH numbered 1 and 2
F/O Standards (Meets or Exceeds)ITU G 657.A2, Fibre sub unit: Water penetration (no leakage)> 1m/24h optical core
Fiber Attenuation< 0.4 dB/km @ 1310nm, < 0.3 dB/km @1550nm

Testing and Environmental

Storage Temperature °C (°F)-20 to 70 (-4 to 158 )
Operation Temperature °C (°F)-20 to 70 (-4 to 158 )
Installation Temperature °C (°F)-20 to 70 (-4 to 158 )
Jacket SpecificationsFlame Retardant IEC60332-1/-3-24, UV Resistance EN 50290-2-24, Halogen Free compliance to IEC60754-1/-2 , Low smoke emission to IEC61034-2
LSZH SpecificationHalogen Free compliance to IEC60754-1/-2 , Low smoke emission to IEC61034-2

External Document Links

Notes