Error: API error: The supplied UserAgent is not allowed: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com) KD-C70 Series Dehydrator - KD-C - RFS Technologies an Amphenol Company
RFS Technologies website is optimized for recent browsers :
IE9+, Chrome 31+, Firefox 31+, Opera 28+, Safari 7+


My e-catalog

KD-C70 Series Dehydrator
KD-C70 Desiccant Dehydrator, 0.71 SCFM, 1200L/h, 0.2 to 7psi Field Adjustable Pressure

Rev : D | Rev date : 13 Nov 2024

The KD-C70 series dehydrators provide a cost-effective solution to pressurize elliptical waveguides, coaxial cables, rigid transmission lines, and antenna systems reliably. By utilizing dry pressurized air in the distribution system, condensation is prevented, ensuring optimal system performance.

The KD-C70 series dehydrators operate automatically once powered on, supplying dry air and maintaining the output pressure within the specified range. They utilize high performance, cobalt-free allochroic silica gel as the desiccant to absorb moisture and dry the air safely and efficiently. The dehydrator is equipped with a desiccant display window for users to conveniently check the dryness of the output air and the condition of the desiccant. The desiccant can be easily taken out and filed back to the dehydrator after being regenerated by a quick heating process using a microwave oven or traditional oven.

FEATURES / BENEFITS

  • High flow rate and capacity to support large size telecom, medium size broadcasting and radar applications: 0.71SCFM or 20.L/min (+/-10% at 25°C)
  • Pre-programed in the factory to minimize installation time on the site.
  • High pressure, low pressure, and excess run come as standard configuration.
  • 4 gas outlet ports with supplied tubing support up to 4 transmission lines, optional gas distribution manifold is available.
  • Unique leakage detection function aids in inspecting the airtighness of the system.
  • Support local or remote management using web browsers
  • Provide audible and visible alarm signal, as well as alarm port for external monitor systems.
  • 110VAC, 220VAC and 48VDC power models available.


Technical features

General Specifications

Product Model   KD-C70 KD-C72 KD-C74-DC
Dehydrator Type   Manual Desiccant Regeneration, Automatic Pressurization
System Capacity   Medium
60 Hz Output Capacity Nl/h (SCFM)   1200 (0.71) +/- 10% 1200 (0.71) +/- 10% 1080 (0.64) +/- 10%
50 Hz Output Capacity Nl/h (SCFM)   1080 (0.64) +/- 10% 1080 (0.64) +/- 10%
Output Dew Point °C (°F)

Better Than -30 (-22)

Factory Set Output Pressure (on/off) kPa (psig) 21 / 35 (3 / 5)
Field Adjustable Output Pressure Range kPa (psig) Field configurable from 1 - 50 (0.2 - 7)
Number of Outlets   4
Output Fitting   Push-on quick fit for 3/8" OD tube
Network Management   Web Browser

Electrical Specifications

Product Model   KD-C70 KD-C72 KD-C74-DC
Operating Voltage V 110 +/- 10%, 60Hz 220 +/- 10%, 50/60Hz -48VDC +/- 10%
Max. Active Current A 1.1 0.6 2.5
Max. Power Consumption Watt 120
Electrical Feed Circuit Configuation   Single phase, 3-Conductor (Phase/Neutral/Ground)  
Electrical Inlet Connector   IEC 320 Type C 14  
Alarm Port   Relay Contact, Load Capacity 30VDC/1.0A or 125VAC/0.5A

Environmental Specifications

Ambient Temperature Range °C (°F)-25 to 50 (-13 to 122 )
Ambient Humidity Range, relative%0 - 95
Noise, dBA @ 1 m, ActivedBA65

MECHANICAL SPECIFICATIONS

Dimensions, H x W x Dmm (in)275 x 315 x 150 (10.8 x 12.4 x 5.9)
Net Weight kg (lb)7.3 (16.1)
Mounting

Desktop and Wall Mount

Interface

Front Panel IndicatorsAlarm (red), Working (green), L D (yellow)
Display4 Segment Numeric Display to Show Pressure Values, and Log Information
Control Buttons4, including +Add/P, -Dec/Q, Set and LeakDetection buttons
Alarm TerminalAlarm Summary and Power Failure, 3 Pin Dry Contact NC, COM, NO

Alarms

Alarm ConfigurationLow Pressure Alarm, High Pressure Alarm, Excess Run Alarm
Alarm Contact RatingDry Contact, 30VDC 1A or 125VAC 0.5A
Low Pressure AlarmFactory set at 0.1 psi lower than the low pressure limit setting
High Pressure AlarmFactory set at 0.5 psi higher than the high pressure limit setting
Excess Run Alarm minutes30
Event LogUnit Power-on Time, Number of Inflating

Compliance

Compliance

CE, RoHS

LVD: EN60204-1:2006+AC:2010

Standard Accessories

Item Quantity

Description

Power Cord 1 pc 6ft (1.8m) long, 110V and 220V AC models with plug, 48V DC model has lugs
Fuse 2 pcs Spare fuse
Gas Inlet Adaptor 4 pcs 1/8 thread and 3/8" OD screw-on
Plastic Tube 33 ft (10m) Black, 3/8" OD
Teflon Tape 1 roll For Air-tightness in Connections
Bracket 1 pair For wall mount
3.5mm Plug 1 pc For connecting alarm port to external monitoring system

Optional Accessories and Maintenance Kit

Item Quantity

Part Number

Desiccant Replacement Kit 1 pc KD27002

Notes

1) All specifiactions at 23°C (73°F) and 50% relative humidity at mean sea level (MSL) unless otherwise noted.