RFS Technologies website is optimized for recent browsers :
IE9+, Chrome 31+, Firefox 31+, Opera 28+, Safari 7+


My e-catalog

FONF-MU06S-XXXM
HYBRIFLEX® Fiber Optic Cable Assembly, MTP12/APC Male to 12 x SC/APC, LSZH, Indoor

Rev : B | Rev date : 03 Mar 2022
HYBRIFLEX fiber only cable assemby, 12 single mode fibers, pre-terminated with an MTP12 male connector on one end and 12 SC/APC connectors on the other end of the LSZH, indoor cable. Optimized for Radio over Fiber (RoF) applications, for use within the RFS Technologies "Plug and Play" RoF solution.

FEATURES / BENEFITS

  • High precision MTP/APC and SC/APC fiber connectors provide low insertion loss, high return loss,excellent stability and durability
  • Mechanical branching system ensures full strain relief
  • Customized lengths are available in addition to the 3m standard version
  • All connectors are terminated and tested in controlled conditions to ensure optimum performance and reliability
  • RFS' "Plug and Play" solution simplifies network design, minimizes installation/testing time and the necessary on site skills

 

 


Technical features

Structure

Cable Type12 single mode fibers (G657A2), LSZH jacket, yellow
Number of Fiber12

Mechanical Specifications

Outer Diameter Nominal mm (in)3 (0.118)
Minimum Bending Radius, (Operating)mm (in)30 (1.181)
Minimum Bending Radius, (Installation)mm (in)50 (1.969)
Tensile Strength (Operating)30 N
Tensile Strength (Installation)100 N
Crush Resistance (Operating)100 N / 10 cm
Crush Resistance (Installation)500 N / 10 cm

Cable Jacket

Jacket MaterialLSZH

F/O Cable Specifications

Core/Clad µm9 /125
F/O Cable JacketLSZH
F/O Standards (Meets or Exceeds)G657A2
Fiber Termination End 1MTP/APC male, single mode, yellow housing, IEC 61754-7
Fiber Termination End 212 x SC/APC simplex
FO Break-out lengthmm(in)600 +/-100
Fiber Attenuation≤ 0.36dB/km λ=1310nm ; ≤0.22dB/km λ =1550nm
Connector Insertion LossMTP(SM): Max. 0.35 dB @ 1310&1550nm/ IEC 61300-3-4 Method B ; SC/APC(SM): Max. 0.30 dB @ 1310&1550nm/ IEC 61300-3-4 Method B
Connector Return LossMTP(SM): Min. 60 dB @ 1310&1550nm ; SC/APC(SM): Min. 60 dB @ 1310&1550nm

Testing and Environmental

Storage Temperature °C (°F)-25 to 70 (-13 to 158 )
Operation Temperature °C (°F)-20 to 60 (-4 to 140 )
Installation Temperature °C (°F)-10 to 55 (14 to 131 )

Ordering Information

L<30M 1 pc in Bag

Additional Assemblies

LengthModel Name
1 mFONF-MU06S-001M
2 mFONF-MU06S-002M
3 mFONF-MU06S-003M
4 mFONF-MU06S-004M
5 mFONF-MU06S-005M
6 mFONF-MU06S-006M
7 mFONF-MU06S-007M
8 mFONF-MU06S-008M
9 mFONF-MU06S-009M
10 mFONF-MU06S-010M

External Document Links