HB012-1-06U1-M2J
HYBRIFLEX™ Standard LTE, Cabling Solution for 1 RRU
Rev : B | Rev date : 19 Aug 2014
RFS' HYBRIFLEX™ cabling solution for Remote Radio Unit (RRU) combines optical fiber and DC power in a single lightweight aluminum corrugated cable, making it the world's most innovative solution for RRU deployments. It was developed to reduce installation complexity and cost at Cellular sites.
HYBRIFLEX™ cabling solutions allows mobile operators deploying RRU architecture to standardized installation process and eliminates the need and the cost for an internal grounding wire.
The HYBRIFLEX™ cable is part of a site installation kit. It consists of an armored bundle of 2 DC cables, 1 F/O distribution cables and a rip cord to adjust the breakout part of the cable.
FEATURES / BENEFITS
- A corrugated armor with excellent bending characteristics minimizes installation time and enables mechanical protection and EMC shielding
- Outer conductor grounding eliminates typical additional grounding requirement and saves on installation costs
- Lightweight solution and compact design decreases tower loads
- Robust cabling eliminates need for expensive cable trays and conduits
- Installation of stripped fiber optic cable pairs directly to RRH reduces CAPEX and wind load by eliminating need for junction boxes
- F/O and DC housed in single corrugated cable saves CAPEX by standardizing RRH cable installation and reducing installation equipments
HYBRIFLEX Series
Structure |
---|
Cable Type | | Single RRU HYBRIFLEX™ Standard LTE | Size | | 1/2 | Fire Performance | | Halogene Free |
|
Mechanical Specifications |
---|
Outer Diameter Nominal | mm (in) | 15.8 (0.62) | Cable Weight | kg/m (lb/ft) | 0.23 (0.155) | Minimum Bending Radius, (Operating) | mm (in) | 70 (2.7) | Minimum Bending Radius, (Installation) | mm (in) | 125 (5) | Tensile Strength | N (lb) | 150 (33.7) | Recommended / Maximum Clamp Spacing | m (ft) | 0.6 / 1 (2 / 3.25) |
|
DC Power Cable Specifications |
---|
Number of DC Pairs | | 1 | Maximum DC-Resistance Power Cable | Ω/km (Ω/kft) | 3.3 (1) | Cross Section of Power Cable | mm² (AWG) | 6 (10) | Shielding | | provided by the Al armor | DC Wire Jacket Material | | Polyethylene, PE | DC Wire Jacket Thickness | mm (in) | 0.5 (0.02) | DC Cable Single Bending Radius | mm (in) | 25 (0.98) | DC Cable Diameter | mm (in) | 5 (0.19) | DC Cable Jacket | | UV stable black PE | DC Standards (Meets or Exceeds) | | IEC 60228 |
|
Cable Jacket |
---|
UV-Protection Individual and External Jacket | | Yes | Jacket Material | | UV stable black PE |
|
Armor Specifications |
---|
Armor Type | | Corrugated Aluminum tube | Maximum DC-Resistance of Armor | Ω/km (Ω/kft) | 2.78 (0.85) | Copper Equivalent Cross Section of Armor | mm² (AWG) | 8 (8) | Diameter Corrugated Armor | mm (in) | 13.8 (0.54) |
|
F/O Cable Specifications |
---|
F/O Cable Type | | Tight Buffer, Multimode | Number of F/O Pairs | | 2 | Core/Clad | µm | 50 /125 | Secondary Protection Nominal | µm (in) | 900 (0.035) | Single Bending Radius | mm (in) | 50 (1.97) | Cable Diameter mm (in) | | 4.8 (0.19) | F/O Cable Jacket | | UV stable black PE | F/O Standards (Meets or Exceeds) | | IEC 60793-2-10 |
|
Testing and Environmental |
---|
Storage Temperature | °C (°F) | -40 to 85 (-40 to 185 ) | Operation Temperature | °C (°F) | -40 to 85 (-40 to 185 ) | Installation Temperature | °C (°F) | -20 to 50 (-4 to 122 ) | Jacket Specifications | | not applicable | LSZH Specification | | not applicable |
|