RFS Technologies website is optimized for recent browsers :
IE9+, Chrome 31+, Firefox 31+, Opera 28+, Safari 7+


My e-catalog

LCF12-50J
1/2" CELLFLEX® Low-Loss Foam-Dielectric Coaxial Cable

Distributor Stock
RF Specialties of PA 3139 Buy
Windy City Wire 6945 Buy
Talley 39187 Buy
Graybar 13863 Buy
Graybar 550 Buy
Rev : J | Rev date : 29 Aug 2024

CELLFLEX® 1/2" low loss flexible cable support CBRS, C-Band and LAA up to 6GHz

 

FEATURES / BENEFITS

  • Ultra Low Attenuation
    The reduced attenuation of CELLFLEX® coaxial cable results in extremly efficient signal transfer in your RF system, especially at high frequencies. 
  • Complete Shielding
    The solid outer conductor of CELLFLEX® coaxial cable creates a continuous RFI/EMI shield that minimizes system interference. 
  • Low VSWR
    Special low VSWR versions of CELLFLEX® coaxial cables contribute to low system noise. 
  • Outstanding Intermodulation Performance
    CELLFLEX® coaxial cable's solid inner and outer conductors virtually eliminate intermods. Intermodulation performance is also confirmed with state-of-the-art equipment at the RFS Technologies factory. 
  • High Power Rating
    Due to their low attenuation, outstanding heat transfer properties and temperature stabilized dielectric materials, CELLFLEX® cable provides safe long term operating life at high transmit power levels. 
  • Wide Range of Application
    Typical areas of application are: feedlines for broadcast and terrestrial microwave antennas, wireless cellular, PCS and ESMR base stations, cabling of antenna arrays, and radio equipment interconnects


External Document Links

Notes

Technical features

INFORMATION

ApplicationsOEM jumpers, Main feed transitions to equipment, GPS lines, intended for outdoor usage

STRUCTURE

Size1/2
Inner Conductor Diameter mm (in)4.8 (0.189)
Inner Conductor MaterialCopper-Clad Aluminum Wire
Dielectric Diameter mm (in)11.3 (0.445)
Dielectric MaterialFoam Polyethylene
Outer Conductor Diameter mm (in)13.8 (0.543)
Outer Conductor MaterialCorrugated Copper
Jacket Diameter mm (in)15.8 (0.622)
Jacket MaterialBlack Polyethylene

TESTING AND ENVIRONMENTAL

Phase Stabilized

Phase stabilized and phase matched cables and accessories are available upon request.

Compliance

DIN EN ISO 9001:2015

ISO 14001:2015

RoHS 2011/65/EU - China RoHS SJ/T 11364-2006

REACH (EC 1907/2006)

UL1581 - UV Resistance Jacket

IEC 60754-1/-2 

Installation Temperature °C(°F)-40 to 60 (-40 to 140)
Storage Temperature °C (°F)-70 to 85 (-94 to 185)
Operation Temperature °C(°F)-50 to 85 (-58 to 185)

ELECTRICAL SPECIFICATIONS

Impedance Ω50 +/- 1
Maximum Frequency GHz8.8
Velocity %87
Capacitance pF/m (pF/ft)76 (23.2)
Inductance uH/m (uH/ft)0.19 (0.058)
Peak Power Rating kW38
RF Peak Voltage Volts1950
Jacket Spark Volt RMS8000
Inner Conductor dc Resistance Ω/1000 m (Ω/1000 ft)1.62 (0.5)
Outer Conductor dc Resistance Ω/1000 m (Ω/1000 ft)3.55 (1.08)
Return Loss (VSWR) Performance20 (1.22) @ 450-617 MHz
24 (1.13) @ 617-960 MHz
24 (1.13) @ 1695-2200 MHz
20 (1.22) @ 2300-2700 MHz
18 (1.28) @ 3500-4200 MHz
16 (1.37) @ 5150-6000 MHz

MECHANICAL SPECIFICATIONS

Cable Weight, Nominal kg/m (lb/ft)0.18 (0.125)
Minimum Bending Radius, Single Bendmm (in)70 (2.756)
Minimum Bending Radius, Repeated Bendsmm (in)125 (4.921)
Bending Moment Nm (lb-ft)6.5 (4.79)
Tensile Strength N (lb)1050 (236)
Recommended / Maximum Clamp Spacing m (ft)0.6 / 1 (2 / 3.25)

ATTENUATION @ 20°C (68°F) AND POWER RATING @ 40°C (104°F)

Frequency, MHzdB per 100mdB per 100ftPower, kW
10.210.0635.34
1002.180.663.45
2003.120.952.41
4504.771.451.57
7006.031.831.24
8006.481.971.16
9006.912.101.09
180010.093.070.74
200010.703.260.70
220011.283.440.67
240011.843.610.63
270012.663.860.59
300013.434.010.56
350014.674.470.51
400015.844.830.47
500018.035.510.42
600020.076.140.37
700022.06.730.34
880025,247.730.30