RLK78-50JFNA
7/8" RADIAFLEX® RLK Cable, A-series
Rev : P1 | Rev date : 08 Mar 2017
- RADIAFLEX® functions as a distributed antenna to provide communications in tunnels, mines and large building complexes and is the solution for any application in confined areas.
- Slots in the copper outer conductor allow a controlled portion of the internal RF energy to be radiated into the surrounding environment. Conversely, a signal transmitted near the cable will couple into the slots and be carried along the cable length.
- RADIAFLEX® is used for both one-way and two-way communication systems and because of its broadband capability, a single radiating cable can handle multiple communication systems simultaneously.
- This RADIAFLEX® radiating cable utilize a low-loss cellular polyethylene foam dielectric and a smooth copper outer conductor which offers a superior electrical performance together with good bending properties.
FEATURES / BENEFITS
- Broadband from 30 MHz to 980 MHz
- For applications in tunnels and buildings
- Low coupling loss variations
RLK cable, A-series
General Specifications |
---|
Size | | 7/8 |
|
Electrical Specifications |
---|
Max. Operating Frequency | MHz | 980 | Cable Type | | RLK | Impedance | Ohm | 50 +/- 2 | Velocity, percent | % | 89 | Capacitance | pF/m (pF/ft) | 75 (22.9) | Inductance, uH/m (uH/ft) | µH/m (µH/ft) | 0.188 (0.057) | DC-resistance inner conductor, ohm/km (ohm/1000ft) | Ω/km (Ω/1000ft) | 1.74 (0.53) | DC-resistance outer conductor, ohm/km (ohm/1000ft) | Ω/km (Ω/1000ft) | 2.52 (0.77) | Stop bands | MHz | 300-375, 650-685 | Frequency Selection | MHz | 600, 900 |
|
Mechanical Specifications |
---|
Jacket | | JFN | Jacket Description | | Halogen free, non corrosive, flame and fire retardant, low smoke, polyolefin | Slot Design | | Groups of vertical slots at short intervals | Inner Conductor Material | | Copper Tube | Outer Conductor Material | | Overlapping Copper Strip | Diameter Inner Conductor | mm (in) | 9.3 (0.37) | Diameter Outer Conductor | mm (in) | 23.8 (0.94) | Diameter over Jacket Nominal | mm (in) | 28.5 (1.12) | Minimum Bending Radius, Single Bend | mm (in) | 350 (13.8) | Cable Weight | kg/m (lb/ft) | 0.55 (0.37) | Tensile Force | N (lb) | 2300 (507) | Indication of Slot Alignment | | Bulge atop slots | Recommended / Maximum Clamp Spacing | m (ft) | 0.9 (3) | Minimum Distance to Wall | mm (in) | 80 (3.15) |
|
Testing and Environmental |
---|
Jacket Testing Methods | | Test methods for fire behaviour of cable : IEC 60754-1/-2 smoke emission: halogen free, non corrosive IEC 61034 low smoke IEC 60332-1 flame retardant IEC 60332-3-24 fire retardant UL1666, ASTM E 662, NES711 and NES713 |
|
Temperature Specifications |
---|
Storage Temperature | °C(°F) | -70 to 85 (-94 to 185 ) | Installation Temperature | °C(°F) | -25 to 60 (-13 to 140 ) | Operation Temperature | °C(°F) | -40 to 85 (-40 to 185 ) |
|
Attenuation | Frequency, MHz | Longitudinal Loss, dB/100 m (dB/100 ft) | Coupling Loss 50%, dB | Coupling Loss 95%, dB |
75 |
1.08 (0.33) |
46 (50) |
58 (60) |
150 |
1.56 (0.48) |
54 (58) |
66 (69) |
380 |
2.69 (0.81) |
53 (55) |
57 (59) |
400 |
2.70 (0.82) |
53 (55) |
57 (59) |
450 |
2.90 (0.88) |
52 (55) |
56 (59) |
470 |
2.97 (0.91) |
52 (55) |
56 (59) |
500 |
3.10 (0.94) |
52 (55) |
56 (59) |
800 |
4.35 (1.33) |
55 (58) |
59 (62) |
870 |
4.90 (1.49) |
56 (59) |
61 (64) |
900 |
5.05 (1.54) |
57 (60) |
62 (65) |
960 |
5.19 (1.58) |
57 (60) |
62 (65) |
|
Notes
- Coupling loss as well as longitudinal attenuation of RADIAFLEX® cables are measured by the free space method according to IEC 61196-4.
- Coupling loss values are measured with a radial (below 330 MHz) or parallel (above 330 MHz) orientated dipole antenna.
- The coupling loss values given in brackets are average values of all three spatial orientations (radial, parallel and orthogonal) of dipole antenna.
- Coupling loss values are given with a tolerance of +10 dB and longitudinal loss values with a tolerance of +5%. Note: Measured values below nominal are better. They are not limited by any tolerance-range.
- In case of a conflict of operational and stop band, please contact RFS Technologies for further assistance.
- As with any radiating cable, the performance in building or tunnel environments may deviate from figures based on free space method.