RLKU114-50JFLAH
1-1/4" RADIAFLEX® RLKU Cable, A-series
Rev : P2 | Rev date : 19 Sep 2024
- RADIAFLEX® functions as a distributed antenna to provide communications in tunnels, mines and large building complexes and is the solution for any application in confined areas.
- Slots in the copper outer conductor allow a controlled portion of the internal RF energy to be radiated into the surrounding environment. Conversely, a signal transmitted near the cable will couple into the slots and be carried along the cable length.
- RADIAFLEX® is used for both one-way and two-way communication systems and because of its broadband capability, a single radiating cable can handle multiple communication systems simultaneously.
- This RADIAFLEX® radiating cable utilize a low-loss cellular polyethylene foam dielectric and a smooth copper outer conductor which offers a superior electrical performance together with good bending properties.
FEATURES / BENEFITS
- Ultra wideband from 30 MHz to 2700 MHz
- For applications in tunnels and buildings
- Low coupling loss variations
picture shows generic slot pattern
General Specifications |
---|
Size | | 1-1/4 |
|
Electrical Specifications |
---|
Max. Operating Frequency | MHz | 2700 | Cable Type | | RLKU | Impedance | Ohm | 50 +/- 2 | Velocity, percent | % | 90 | Capacitance | pF/m (pF/ft) | 74 (22.6) | DC-resistance inner conductor, ohm/km (ohm/1000ft) | Ω/km (Ω/1000ft) | 0.83 (0.253) | DC-resistance outer conductor, ohm/km (ohm/1000ft) | Ω/km (Ω/1000ft) | 1.75 (0.534) | Stop bands | MHz | 540-610 | Frequency Selection | MHz | 600, 900, 1800/1900, 2200, 2400, 2500, 2700 |
|
Mechanical Specifications |
---|
Jacket | | JFL, EN50575:2017 classified cable | Jacket Description | | Halogen free, non corrosive, flame and fire retardant, low smoke, polyolefin + flame barrier tape above outer conductor for lowest cable loss | Slot Design | | Groups of vertical slots at short intervals | Inner Conductor Material | | Corrugated Copper Tube | Outer Conductor Material | | Overlapping Copper Strip | Diameter Inner Conductor | mm (in) | 13.9 (0.55) | Diameter Outer Conductor | mm (in) | 34 (1.34) | Diameter over Jacket Nominal | mm (in) | 38.1 (1.5) | Minimum Bending Radius, Single Bend | mm (in) | 500 (20) | Cable Weight | kg/m (lb/ft) | 0.87 (0.58) | Tensile Force | N (lb) | 2000 (440) | Indication of Slot Alignment | | Guides opposite to slots | Recommended / Maximum Clamp Spacing | m (ft) | 1.3 (4.3) | Minimum Distance to Wall | mm (in) | 80 (3.15) |
|
Testing and Environmental |
---|
Jacket Testing Methods | | Test methods for fire behaviour of cable : IEC 60754-1/-2 smoke emission: halogen free, non corrosive IEC 61034 low smoke IEC 60332-1 flame retardant IEC 60332-3-24 fire retardant NFPA130 (ed. 2014) Ch.12 (NFPA70 ) via UL-1685/FT4/IEEE1202 UL1666, ASTM E 662, NES711 and NES713 EN50575:2017 (Hannover production) class Dca s1 d2 a1 |
|
Temperature Specifications |
---|
Storage Temperature | °C(°F) | -70 to 85 (-94 to 185 ) | Installation Temperature | °C(°F) | -25 to 60 (-13 to 140 ) | Operation Temperature | °C(°F) | -40 to 85 (-40 to 185 ) |
|
Attenuation | Frequency, MHz | Longitudinal Loss, dB/100 m (dB/100 ft) | Coupling Loss 50%, dB | Coupling Loss 95%, dB |
75 |
0.71 (0.23) |
58 (61) |
68 (71) |
150 |
1.08 (0.33) |
64 (67) |
75 (78) |
500 |
2.03 (0.62) |
69 (73) |
81 (84) |
700 |
2.55 (0.78) |
62 (65) |
66 (69) |
800 |
2.75 (0.84) |
62 (65) |
67 (70) |
860 |
2.88 (0.88) |
67 (70) |
73 (76) |
870 |
2.90 (0.89) |
68 (71) |
74 (77) |
900 |
2.97 (0.91) |
64 (67) |
67 (70) |
1900 |
5.39 (1.64) |
62 (65) |
67 (70) |
2000 |
5.69 (1.64) |
63 (66) |
69 (72) |
2100 |
5.96 (1.82) |
62 (65) |
67 (70) |
2200 |
6.37 (1.94) |
61 (64) |
66 (69) |
2300 |
6.79 (2.07) |
62 (65) |
67 (70) |
2400 |
7.32 (2.23) |
61 (64) |
67 (70) |
2700 |
9.12 (2.78) |
61 (64) |
67 (70) |
|
Notes
- Coupling loss as well as longitudinal attenuation of RADIAFLEX® cables are measured by the free space method according to IEC 61196-4.
- Coupling loss values are measured with a radial (below 550 MHz) or parallel (above 550 MHz) orientated dipole antenna.
- The coupling loss values given in brackets are average values of all three spatial orientations (radial, parallel and orthogonal) of dipole antenna.
- Coupling loss values are given with a tolerance of +5 dB and longitudinal loss values with a tolerance of +5%. Note: Measured values below nominal are better. They are not limited by any tolerance-range.
- In case of a conflict of operational and stop band, please contact RFS Technologies for further assistance.
- As with any radiating cable, the performance in building or tunnel environments may deviate from figures based on free space method.
;