RFS Technologies website is optimized for recent browsers :
IE9+, Chrome 31+, Firefox 31+, Opera 28+, Safari 7+


My e-catalog

RLKU12-50JFLA
1/2" RADIAFLEX® RLKU Cable, A-series

Rev : P1 | Rev date : 19 Sep 2024
  • RADIAFLEX® functions as a distributed antenna to provide communications in tunnels, mines and large building complexes and is the solution for any application in confined areas.
  • Slots in the copper outer conductor allow a controlled portion of the internal RF energy to be radiated into the surrounding environment. Conversely, a signal transmitted near the cable will couple into the slots and be carried along the cable length.
  • RADIAFLEX® is used for both one-way and two-way communication systems and because of its broadband capability, a single radiating cable can handle multiple communication systems simultaneously.
  • This RADIAFLEX® radiating cable utilize a low-loss cellular polyethylene foam dielectric and a smooth copper outer conductor which offers a superior electrical performance together with good bending properties.

FEATURES / BENEFITS

  • Ultra wideband from 30 MHz to 2700 MHz
  • For applications in tunnels and buildings
  • Low coupling loss variations


RLK12-50JFLA

Technical features

General Specifications

Size1/2

Electrical Specifications

Max. Operating Frequency MHz2700
Cable TypeRLKU
ImpedanceOhm50 +/- 2
Velocity, percent%88
Capacitance pF/m (pF/ft)76 (23.2)
Inductance, uH/m (uH/ft)µH/m (µH/ft)0.19 (0.058)
DC-resistance inner conductor, ohm/km (ohm/1000ft)Ω/km (Ω/1000ft)1.97 (0.6)
DC-resistance outer conductor, ohm/km (ohm/1000ft)Ω/km (Ω/1000ft)4.84 (1.48)
Stop bands MHz650-750, 1330-1430, 2025-2100
Frequency Selection MHz600, 900, 1800/1900, 2200, 2400, 2500, 2700

Mechanical Specifications

JacketJFL
Jacket DescriptionHalogen free, non corrosive, flame and fire retardant, low smoke, polyolefin + flame barrier tape above outer conductor for lowest cable loss
Slot DesignGroups of vertical slots at short intervals
Inner Conductor MaterialCopper Clad Aluminum Wire
Outer Conductor MaterialOverlapping Copper Strip
Diameter Inner Conductor mm (in)4.4 (0.17)
Diameter Outer Conductor mm (in)11.4 (0.45)
Diameter over Jacket Nominal mm (in)14.7 (0.58)
Minimum Bending Radius, Single Bend mm (in)200 (7.9)
Cable Weight kg/m (lb/ft)0.23 (0.16)
Tensile ForceN (lb)1300 (292)
Indication of Slot AlignmentBulge atop slots
Recommended / Maximum Clamp Spacing m (ft)0.5 (1.6)
Minimum Distance to Wall mm (in)80 (3.15)

Testing and Environmental

Jacket Testing MethodsTest methods for fire behaviour of cable :
IEC 60754-1/-2 smoke emission: halogen free, non corrosive
IEC 61034 low smoke
IEC 60332-1 flame retardant
IEC 60332-3-24 fire retardant
UL1666, ASTM E 662, NES711, NES713 and NFPA130

Temperature Specifications

Storage Temperature °C(°F)-70 to 85 (-94 to 185 )
Installation Temperature °C(°F)-25 to 60 (-13 to 140 )
Operation Temperature °C(°F)-40 to 85 (-40 to 185 )

Attenuation

Frequency, MHzLongitudinal Loss, dB/100 m (dB/100 ft)Coupling Loss 50%, dBCoupling Loss 95%, dB
75 2.17 (0.66) 49 (53) 59 (63)
150 3.10 (0.94) 57 (61) 68 (72)
450 5.74 (1.75) 65 (68) 76 (79)
800 8.75 (2.67) 57 (59) 63 (65)
870 9.21 (2.81) 58 (60) 64 (66)
900 9.40 (2.86) 58 (60) 63 (66)
960 9.73 (2.97) 58 (60) 64 (66)
1800 21.97 (6.70) 55 (57) 65 (67)
1900 22.71 (6.92) 55 (57) 65 (67)
2000 23.48 (7.16) 53 (56) 65 (66)
2200 25.47 (7.76) 52 (55) 60 (63)
2400 27.93 (8.51) 52 (54) 60 (63)
2600 30.50 (9.30) 52 (54) 60 (63)

External Document Links

Notes

  • Coupling loss as well as longitudinal attenuation of RADIAFLEX® cables are measured by the free space method according to IEC 61196-4.
  • Coupling loss values are measured with a radial (below 650 MHz) or parallel (above 650 MHz) orientated dipole antenna.
  • The coupling loss values given in brackets are average values of all three spatial orientations (radial, parallel and orthogonal) of dipole antenna.
  • Coupling loss values are given with a tolerance of +5 dB and longitudinal loss values with a tolerance of +5%. Note: Measured values below nominal are better. They are not limited by any tolerance-range.
  • In case of a conflict of operational and stop band, please contact RFS Technologies for further assistance.
  • As with any radiating cable, the performance in building or tunnel environments may deviate from figures based on free space method.