RFS Technologies website is optimized for recent browsers :
IE9+, Chrome 31+, Firefox 31+, Opera 28+, Safari 7+


My e-catalog

EP65
FLEXWELL® Elliptical Waveguide, Operating Band 5.9 to 7.125GHz

Distributor Stock
RF Specialties of PA 3034 Buy
Rev : B | Rev date : 18 Apr 2024
FLEXWELL® elliptical waveguide is constructed of longitudinally continuous seam welded, highly conductive copper tube, corrugated and precision formed into an elliptical cross section. It is manufactured in continuous lengths using a special seam welding process.

The corrugation design achieves high transverse stability, flexibility and crush strength for superior handling and forming at an installation. The inherent strength and flexibility of FLEXWELL® waveguide allows on location, a continuous length of waveguide to be run directly from a tower-mounted antenna to the equipment building.

A FLEXWELL® elliptical waveguide feeder requires less planning and reduces installation costs when compared to a feeder system using a rigid rectangular waveguide.
FLEXWELL® waveguide is available cut to length with factory attached connectors or in continuous lengths for termination in the field.

FEATURES / BENEFITS

  • Designed for optimum system performance
  • Excellent electrical performance
  • Low loss and low VSWR (low return loss)
  • Electrical test made on every waveguide during manufacturing
  • Every waveguide passes pressure test
  • Reduced installation cost and time compared to using rigid rectangular waveguides
  • No need of flange joints, twist section and bends
  • Easy transportation in coils or on drums
  • Cutting at exact length and connectorizing in the field or in the factory


Technical features

General Specifications

PerformanceStandard (STD) or Premium (PREM) to be selected when ordering
JacketJ ( Black Polyethylene, PE) by default, JFN (Black fire redartant) on request

Electrical Specifications

Typical Operating Band GHz5.9 - 7.125
Max. VSWR / Return Loss dB1.062 / 30.5 Premium Performance (suggest to use with tunable or pre-tuned connectors to achieve optimal system performance)
1.15 / 23.1 Standard Performance
Cut-off Frequency GHz4.01

Mechanical Specifications

Dimension over Jacket mm (in)51 x 30 (2.0 x 1.2)
Weight kg/m (lb/ft)0.75 (0.5)
Minimum Bending Radius E Plane, Single Bendmm (in)200 (8)
Minimum Bending Radius H Plane, Single Bendmm (in)500 (20)
Minimum Bending Radius E Plane, Repeated Bendsmm (in)300 (12)
Minimum Bending Radius H Plane, Repeated Bendsmm (in)600 (24)
Maximum Twist degree/m (degree/ft)5 (1.5)
Max. Operating Pressure bar (psi)0.5 (7)
Max. Pulling Length per Hoisting Grip m (ft)100 (305)
Standard Hanger Spacing m (ft)0.9 (3)

Temperature Specifications

Installation Temperature°C (°F)-40 to 60 (-40 to 140 )
Storage Temperature °C (°F)-70 to 85 (-94 to 185 )
Operation Temperature°C (°F)-50 to 85 (-58 to 185 )

Attenuation and Power Rating

Frequency (GHz)Attenuation dB/100mAttenuation dB/100ftAvarage Power (KW)Group velocity (%c)Group Delay (ns/100m)Group Delay (ns/100ft)
5.9 4.92 1.50 4.82 73.4 454.7 138.6
6 4.84 1.47 4.90 74.4 448.4 136.7
6.1 4.76 1.45 4.98 75.4 442.6 134.9
6.2 4.69 1.43 5.06 76.3 437.4 133.3
6.3 4.62 1.41 5.13 77.1 432.5 131.8
6.4 4.56 1.39 5.19 77.9 428 130.5
6.5 4.51 1.37 5.26 78.7 423.8 129.2
6.6 4.46 1.36 5.32 79.4 420 128
6.7 4.41 1.34 5.37 80.1 416.4 126.9
6.8 4.37 1.33 5.42 80.8 413 125.9
6.9 4.33 1.32 5.47 81.4 409.9 124.9
7 4.29 1.31 5.52 82 407 124
7.1 4.25 1.30 5.58 82.7 403.5 123

External Document Links

Notes

Recommend premium performance waveguides to be used with tunable or pre-tuned connectors.

VSWR values include connectors and are valid for frequency band of connectors.

Max. Operating Band: 5.00 - 7.125 GHz