RFS Technologies website is optimized for recent browsers :
IE9+, Chrome 31+, Firefox 31+, Opera 28+, Safari 7+


My e-catalog

HA-FOJBF-OA-01SM-30
HYBRIFLEX® Optical Fiber Cabling Solution, 1 Pair Armored Bend-Insensitive Single-Mode Fiber with ODC to LC/FullAXS Compatible Connectors, 30 m

Rev : J | Rev date : 15 Mar 2022

PRODUCT DESCRIPTION

RFS’ HYBRIFLEX Remote Radio Head (RRH) hybrid feeder cabling solution combines any combination of optical fiber and/or DC power for RRHs in a single lightweight armored or unarmored cable, making it the world’s most innovative solution for RRH deployments. Hybrid, Fiber Optic and DC riser trunk and jumper cables are available in a large variety of fiber counts, DC counts and cross sections. Both pre-connectorized and on-site options are available.

FEATURES / BENEFITS

  • Armored, bend-insensitive fiber design with outstanding bending characteristics – Eases installation and provides long-term reliability
  • Lightweight solution and compact design – Decreases tower loading
  • Robust cabling – Eliminates need for expensive cable trays and ducts
  • Indoor/Outdoor, black PVC jacket – Ensures long-lasting cable protection
  • 100% Factory tested - Online test results available

TECHNICAL FEATURES

Structure 

Cable Type   HYBRIFLEX®
Fire Performance   Flame Retardant
Lengthm (ft)30 (98.4)

Mechanical Specifications 

Outer Diameter Nominal mm (in) 4.8 (0.189)
Cable Weight kg/m (lb/ft) 0.035 (0.023)
Minimum Bending Radius, Single Bend mm (in) 50 (1.97)
Minimum Bending Radius, Multiple Bends mm (in) 75 (2.95)
Recommended / Maximum Clamp Spacing m (ft) 1 / 1.2 (3.25 / 4)

F/O Cable Specifications

Number of F/O Pairs1
F/O Cable Type   G657-A1 Single Mode, Bend Tolerant
Core/Clad µm 9/125
Secondary Protection Nominal µm (in) 900 (0.035)
F/O Standards (Meets or Exceeds)   RoHS Compliant
Optical Loss dB/Km 0.5 @ 1310 nm
0.5 @ 1550 nm
Fiber Termination End 1ODC socket
Fiber Termination End 2DLC Connector with FullAXS Compatibility

Cable Jacket 

UV-Protection Individual and External Jacket   Yes
Jacket Material   Flame Retardant, Indoor/Outdoor, Black, LSZH
Armor Type   Metal Armored Tube
Diameter Corrugated Armor mm (in) 2.8 (0.11)

Testing and Environmental

Storage Temperature °C (°F) -40 to 70 (-40 to 158)
Operation Temperature °C (°F) -40 to 65 (-40 to 149)
Installation Temperature °C (°F) -20 to 65 (-4 to 149)

EXTERNAL DOCUMENT LINKS

Installation Guidelines: Download

On-line Factory Test Results: View

NOTES

Additional Assemblies - ODC to DLC 

Model Number Length, m
HA-FOJBF-OL-01SM-1 1
HA-FOJBF-OL-01SM-3 3
HA-FOJBF-OL-01SM-5 5
HA-FOJBF-OL-01SM-10 10
HA-FOJBF-OL-01SM-20 20

Additional Assemblies - ODC to DLC/FullAXS

Model Number Length, m
HA-FOJBF-OA-01SM-1 1
HA-FOJBF-OA-01SM-3 3
HA-FOJBF-OA-01SM-5 5
HA-FOJBF-OA-01SM-10 10
HA-FOJBF-OA-01SM-20 20
HA-FOJBF-OA-01SM-30 30

Additional Assemblies - ODC to DLC/NB 

Model Number Length, m
FOJBF-OB01S-003M 3
FOJBF-OB01S-005M 5

Additional Assemblies - ODC to DLC/R2CT

Model Number Length, m
FOJBF-OC01S-003M 3
FOJBF-OC01S-005M 5
FOJBF-OC01S-010M 10
FOJBF-OC01S-020M 20

Additional Assemblies - ODC to DLC/AOPC 

Model Number Length, m
FOJBF-ON01S-003M 3
FOJBF-ON01S-005M 5
FOJBF-ON01S-010M 10
FOJBF-ON01S-020M 20

Additional Assemblies - ODC to DLC/AOPA 

Model Number Length, m
FOJBF-OPA01S-003M 3
FOJBF-OPA01S-005M 5

Additional Assemblies - ODC to DLC/AOPE 

Model Number Length, m
FOJBF-OPE01S-003M 3
FOJBF-OPE01S-005M 5
FOJBF-OPE01S-010M 10
FOJBF-OPE01S-020M 20

Additional Assemblies - ODC to DLC/AOPE 

Model Number Length, m
FOJBF-OSFP01S-003M 3
FOJBF-OSFP01S-005M 5
FOJBF-OSFP01S-010M 10
FOJBF-OSFP01S-020M 20